• Twitter
  • Jobs
ProCURE oncology
  • HOME
  • ABOUT US
  • RESEARCH GROUP
    • Molleví’s Lab
    • Antolin’s Lab
    • Alemany’s & Piulats’s lab
    • Martínez-Balibrea’s Lab
    • Aytes’s Lab
    • Belver’s Lab
    • Pujana’s Lab
    • Menendez’s Lab
    • Sureda’s & Farre’s Lab
    • Casanovas’s Lab
    • Viñals’s lab
  • INNOVATION
  • NEWS
  • CONTACT
  • Menu Menu

NEWS

Non-invasive monitoring of hypoxia-inducible factor activation by optical imaging during antiangiogenic treatment in a xenograft model of ovarian carcinoma

View in PubMed
14 de June de 2011/in Casanovas's Lab/by miguel

Int J Oncol. 2011 Sep;39(3):543-52. doi: 10.3892/ijo.2011.1074. Epub 2011 Jun 9.

ABSTRACT

Targeting the hypoxia response pathway and angiogenesis are two promising therapeutic strategies for cancer treatment. Their use as single strategies has important limitations. Thus, development of combined regimens has become an important step toward improving therapeutic efficacy. Also, non-invasive monitoring of the response to targeted biological therapies, as well as determination of the optimal schedule for combination regimens has become an active field of research over the last five years, with relevance for both preclinical and clinical settings. Here, we used an optical imaging method to non-invasively monitor the functional changes in HIF activity in response to antiangiogenic treatment in a xenograft model of human ovarian carcinoma. A bioluminescent reporter construct containing nine copies of the hypoxia response element upstream of the luciferase gene (9xHRE-luciferase) was characterized in vitro in a panel of tumor cell lines and in vivo in a subcutaneous xenograft model of ovarian carcinoma by means of optical imaging. We showed that in OVCAR-3 subcutaneous xenografts, the most abrupt change in the HIF functional reporter occurs before the onset of massive tumor growth. However, this system failed to detect hypoxia induced upon antiangiogenic treatment due to the compensating effects of increased hypoxia and decreased tumor cell viability caused by imbalanced neovascularization vs. tumor expansion. Therefore, the readout based on HIF functional reporter could be conditioned by the dynamics of tumor growth and angiogenesis, which is highly variable depending on the tumor type, tumor model and stage of progression.

PMID:21667025 | DOI:10.3892/ijo.2011.1074

https://procure-oncology.com/wp-content/uploads/2023/10/Procure-icoRecurso-1@2x-100.jpg 0 0 miguel https://procure-oncology.com/wp-content/uploads/2023/10/Procure-icoRecurso-1@2x-100.jpg miguel2011-06-14 10:00:002011-06-14 10:00:00Non-invasive monitoring of hypoxia-inducible factor activation by optical imaging during antiangiogenic treatment in a xenograft model of ovarian carcinoma

Filter by categories

  • Alemany’s & Piulats’s lab (131)
  • Antolin's lab (36)
  • Aytes's Lab (24)
  • Belver's Lab (25)
  • Casanovas's Lab (77)
  • Martínez-Balibrea's Lab (43)
  • Menendez's Lab (121)
  • Molleví's Lab (35)
  • Pujana's Lab (110)
  • Sureda's & Farre's Lab (258)
  • Viñals's lab (111)

Twitter

Tweets by ProcureICO
Program Against Cancer Therapeutic Resistance

CONTACT US

Campus IDIBELL
(L’Hospitalet del Llobregat)
Hospital Duran i Reynals, Gran Via 199,
L’Hospitalet del Llobregat,
Barcelona 08908
Tel. +34 93 260 7952

Campus IGTP-IJC
(Badalona)
Campus Can Ruti – IGTP – Building Muntanya,
Rd. Can Ruti, Camí de les escoles s/n,
Badalona, Barcelona 08916
Tel. +34 93 554 3069

Campus IDIBGI
(Girona)
Parc Hospitalari Martí i Julià de Salt, Dr. Castany s/n,
Salt, Girona 17190
Tel. +34 872 987 087

© Copyright - Edisenius
  • Privacy Policy
  • Cookie Policy
  • Legal Notice
Fetal optic nerve sheath measurement as a non-invasive tool for assessment of...Collaborative study on 3-dimensional sonography for the prenatal diagnosis of...
Scroll to top
Manage cookie consent
To offer the best experiences, we use technologies such as cookies to store and/or access device information. Consent to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Failure to consent, or withdrawal of consent, may adversely affect certain features and functions.
Functional Always active
Storage or technical access is strictly necessary for the legitimate purpose of allowing the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. Storage or technical access that is used exclusively for anonymous statistical purposes. Without a requirement, voluntary compliance by your Internet service provider, or additional records from a third party, information stored or retrieved solely for this purpose cannot be used to identify you.
Marketing
Storage or technical access is necessary to create user profiles to send advertising, or to track the user on a website or several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
See preferences
{title} {title} {title}