Fetal optic nerve sheath measurement as a non-invasive tool for assessment of increased intracranial pressure

View in PubMed
18 de May de 2011/in Viñals's lab/by miguel

Ultrasound Obstet Gynecol. 2011 Dec;38(6):646-51. doi: 10.1002/uog.9050. Epub 2011 Nov 11.

ABSTRACT

OBJECTIVES: To describe the sonographic technique for assessment of the fetal optic nerve sheath and to report on three fetuses with intracranial lesions and enlarged optic nerve sheath diameter (ONSD) compared with normal controls matched for gestational age (GA).

METHODS: In this cross-sectional study ONSD was measured sonographically in three fetuses (aged 23, 24 and 35 gestational weeks) with intracranial findings associated with increased intracranial pressure (ICP; dural thrombosis and intracranial tumors) as well as 42 healthy controls matched for GA ± 1 week (aged 22-25 and 34-36 weeks). For fetal eye assessment, transabdominal and transvaginal routes and high-resolution transducers were used for optimal visualization depending on fetal position. Measurements were made using an axial view at the level of the orbits, with the fetal face positioned towards the transducer. The ONSD was measured 1.5 or 2 mm behind the papilla (depending on GA) in all fetuses. Mean ± 2 SD ONSD of controls were calculated for each GA and compared with data from the three fetuses with intracranial pathology.

RESULTS: In the 42 normal fetuses, ONSD increased from 1.2 mm at 23 weeks to 2.6 mm at 36 weeks. The measurements at 36 weeks correlated well with those observed in newborns. ONSD measurements of the three cases were above mean + 2 SD of values obtained from healthy controls at the same GA and also exceeded values of fetuses that were 1 week older.

CONCLUSIONS: Fetal ONSD measurement is feasible using a technique similar to that used in adults and children. ONSD enlargement was observed in all three fetuses with intracranial lesions and may be an early tool with which to diagnose increased ICP.

PMID:21584889 | DOI:10.1002/uog.9050

https://procure-oncology.com/wp-content/uploads/2023/10/Procure-icoRecurso-1@2x-100.jpg 0 0 miguel https://procure-oncology.com/wp-content/uploads/2023/10/Procure-icoRecurso-1@2x-100.jpg miguel2011-05-18 10:00:002011-05-18 10:00:00Fetal optic nerve sheath measurement as a non-invasive tool for assessment of increased intracranial pressure

Filter by categories

  • Alemany’s & Piulats’s lab (131)
  • Antolin's lab (36)
  • Aytes's Lab (24)
  • Belver's Lab (25)
  • Casanovas's Lab (77)
  • Martínez-Balibrea's Lab (43)
  • Menendez's Lab (121)
  • Molleví's Lab (35)
  • Pujana's Lab (110)
  • Sureda's & Farre's Lab (259)
  • Viñals's lab (111)

Twitter

Tweets by ProcureICO
Program Against Cancer Therapeutic Resistance

CONTACT US

Campus IDIBELL
(L’Hospitalet del Llobregat)
Hospital Duran i Reynals, Gran Via 199,
L’Hospitalet del Llobregat,
Barcelona 08908
Tel. +34 93 260 7952

Campus IGTP-IJC
(Badalona)
Campus Can Ruti – IGTP – Building Muntanya,
Rd. Can Ruti, Camí de les escoles s/n,
Badalona, Barcelona 08916
Tel. +34 93 554 3069

Campus IDIBGI
(Girona)
Parc Hospitalari Martí i Julià de Salt, Dr. Castany s/n,
Salt, Girona 17190
Tel. +34 872 987 087

© Copyright - Edisenius
  • Privacy Policy
  • Cookie Policy
  • Legal Notice
Glycolytic phenotype and AMP kinase modify the pathologic response of tumor...Non-invasive monitoring of hypoxia-inducible factor activation by optical imaging...
Scroll to top
Manage cookie consent
To offer the best experiences, we use technologies such as cookies to store and/or access device information. Consent to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Failure to consent, or withdrawal of consent, may adversely affect certain features and functions.
Functional Always active
Storage or technical access is strictly necessary for the legitimate purpose of allowing the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. Storage or technical access that is used exclusively for anonymous statistical purposes. Without a requirement, voluntary compliance by your Internet service provider, or additional records from a third party, information stored or retrieved solely for this purpose cannot be used to identify you.
Marketing
Storage or technical access is necessary to create user profiles to send advertising, or to track the user on a website or several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
See preferences
{title} {title} {title}