• Twitter
  • Jobs
ProCURE oncology
  • HOME
  • ABOUT US
  • RESEARCH GROUP
    • Molleví’s Lab
    • Antolin’s Lab
    • Alemany’s & Piulats’s lab
    • Martínez-Balibrea’s Lab
    • Aytes’s Lab
    • Belver’s Lab
    • Pujana’s Lab
    • Menendez’s Lab
    • Sureda’s & Farre’s Lab
    • Casanovas’s Lab
    • Viñals’s lab
  • INNOVATION
  • NEWS
  • CONTACT
  • Menu Menu

NEWS

Mobilization of Hematopoietic Stem Cells into Peripheral Blood for Autologous Transplantation Seems Less Efficacious in Poor Mobilizers with the Use of a Biosimilar of Filgrastim and Plerixafor: A Retrospective Comparative Analysis

View in PubMed
24 de July de 2020/in Sureda's & Farre's Lab/by miguel

Oncol Ther. 2020 Dec;8(2):311-324. doi: 10.1007/s40487-020-00115-3. Epub 2020 May 14.

ABSTRACT

INTRODUCTION: Biosimilars of granulocyte colony-stimulating factors (G-CSF) have shown similar efficacy to originator filgrastim (Neupogen® [NEU]; Amgen Inc.) as prophylaxis in neutropenia and in the mobilization of stem cells in patients receiving combination chemotherapy with G-CSF.

METHODS: This was a retrospective study in which the characteristics of stem cell mobilization treated with a G-CSF alone were compared in 216 patients and 56 donors. The two G-CSF compared were NEU and the biosimilar filgrastim Zarzio® (Sandoz GmbH) (referred to hereafter as BIO). Primary objectives were mobilization rate (minimum of 10 × 103/ml CD34+ on day 4 of treatment [day +4]) and use of the immunostimulant plerixafor (PLEX) in each group.

RESULTS: The general characteristics of the patients receiving NEU (n = 138) and those receiving BIO (n = 78) did not differ significantly. PLEX was used in 24% of BIO patients and in 25.7% of NEU patients. The median CD34+ cell count on day +4 was significantly lower in BIO patients who needed PLEX than in those who did not (2.4 vs. 4.8 × 103/ml; p = 0.002), as was the final CD34+ cell count (2.5 vs. 3.3 × 106/kg; p 0.03). Mobilization failure rate was higher in the BIO group than in the NEU group (20 vs. 0%; p = 0.01). With respect to donors, more than one apheresis was needed in three BIO donors, one of them with PLEX. The use of BIO was the only risk factor for mobilization failure in patients who needed PLEX (hazard ratio 10.3; 95% confidence interval 1.3-77.8).

CONCLUSION: The study revealed that BIO had a lower efficacy for stem cell mobilization when the only treatment was G-CSF, especially in poor mobilizers needing PLEX.

PMID:32700041 | PMC:PMC7683658 | DOI:10.1007/s40487-020-00115-3

https://procure-oncology.com/wp-content/uploads/2023/10/Procure-icoRecurso-1@2x-100.jpg 0 0 miguel https://procure-oncology.com/wp-content/uploads/2023/10/Procure-icoRecurso-1@2x-100.jpg miguel2020-07-24 10:00:002020-07-24 10:00:00Mobilization of Hematopoietic Stem Cells into Peripheral Blood for Autologous Transplantation Seems Less Efficacious in Poor Mobilizers with the Use of a Biosimilar of Filgrastim and Plerixafor: A Retrospective Comparative Analysis

Filter by categories

  • Alemany’s & Piulats’s lab (131)
  • Antolin's lab (36)
  • Aytes's Lab (24)
  • Belver's Lab (25)
  • Casanovas's Lab (77)
  • Martínez-Balibrea's Lab (43)
  • Menendez's Lab (121)
  • Molleví's Lab (35)
  • Pujana's Lab (110)
  • Sureda's & Farre's Lab (259)
  • Viñals's lab (111)

Twitter

Tweets by ProcureICO
Program Against Cancer Therapeutic Resistance

CONTACT US

Campus IDIBELL
(L’Hospitalet del Llobregat)
Hospital Duran i Reynals, Gran Via 199,
L’Hospitalet del Llobregat,
Barcelona 08908
Tel. +34 93 260 7952

Campus IGTP-IJC
(Badalona)
Campus Can Ruti – IGTP – Building Muntanya,
Rd. Can Ruti, Camí de les escoles s/n,
Badalona, Barcelona 08916
Tel. +34 93 554 3069

Campus IDIBGI
(Girona)
Parc Hospitalari Martí i Julià de Salt, Dr. Castany s/n,
Salt, Girona 17190
Tel. +34 872 987 087

© Copyright - Edisenius
  • Privacy Policy
  • Cookie Policy
  • Legal Notice
Are antiangiogenics a good ‘partner’ for immunotherapy in ovarian...Arming Oncolytic Adenoviruses: Effect of Insertion Site and Splice Acceptor...
Scroll to top
Manage cookie consent
To offer the best experiences, we use technologies such as cookies to store and/or access device information. Consent to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Failure to consent, or withdrawal of consent, may adversely affect certain features and functions.
Functional Always active
Storage or technical access is strictly necessary for the legitimate purpose of allowing the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. Storage or technical access that is used exclusively for anonymous statistical purposes. Without a requirement, voluntary compliance by your Internet service provider, or additional records from a third party, information stored or retrieved solely for this purpose cannot be used to identify you.
Marketing
Storage or technical access is necessary to create user profiles to send advertising, or to track the user on a website or several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
See preferences
{title} {title} {title}