• Twitter
  • Jobs
ProCURE oncology
  • HOME
  • ABOUT US
  • RESEARCH GROUP
    • Molleví’s Lab
    • Antolin’s Lab
    • Alemany’s & Piulats’s lab
    • Martínez-Balibrea’s Lab
    • Aytes’s Lab
    • Belver’s Lab
    • Pujana’s Lab
    • Menendez’s Lab
    • Sureda’s & Farre’s Lab
    • Casanovas’s Lab
    • Viñals’s lab
  • INNOVATION
  • NEWS
  • CONTACT
  • Menu Menu

NEWS

Liver xenotransplantation: changes in lipid and lipoprotein concentration after long-term graft survival

View in PubMed
27 de April de 2000/in Molleví's Lab/by miguel

J Hepatol. 2000 Apr;32(4):655-60. doi: 10.1016/s0168-8278(00)80228-7.

ABSTRACT

BACKGROUND/AIMS: Today, scientists devote considerable effort to the study of mechanisms of xenograft rejection, but with liver xenotransplantation (XTx) researchers face the added problem of metabolic incompatibility between species. To date, there have been few studies of molecular xenogeneic interactions, perhaps because little progress has been made in solving immunological problems. This study is an initial analysis of lipoprotein metabolism in a hamster-to-rat hepatic xenotransplantation model.

METHODS: There were 6 experimental groups (n=8): (1) male Sprague-Dawley (S.D.) rats (220-280 g); (2) male Golden Syrian hamsters (100-150 g); (3) S.D. rats, “sham” operation with immunosuppression; (4) S.D. rat-to-S.D. rat alloTx; (5) S.D. rat-to-S.D. rat alloTx with immunosuppression; (6) XTx hamster G.S-to-S.D. rat with immunosuppression. Mofetil mycophenolate (25 mg/kg/d) was administered for 14 days and FK506 (0.2 mg/kg/d) for 45 days (groups 3, 5 and 6). After 24 h fasting, animals were sacrificed (day +50 postransplantation) and a complete lipoprotein profile was determined. Serum lipoproteins were subfractioned by ultracentrifugation in density gradient.

RESULTS: There was a large increase in serum lipid levels in xenografted rats compared with control rats and allografted rats. Xenografted rats presented a severely altered lipoprotein profile compared with normal rats. Surprisingly, the characterisation of lipoproteins in xenografted rats displayed the same composition as donor animals. Histological study did not show signs of alteration of the hepatic architecture.

CONCLUSIONS: Since the liver is the main solid organ co-ordinator of metabolic pathways, such as lipid metabolism, hepatic xenotransplantation makes changes in lipid concentrations in the recipient and also changes in lipid compositions of lipoproteins. Hepatic xenotransplantation is not a feasible solution given the organ’s metabolic complexity.

PMID:10782915 | DOI:10.1016/s0168-8278(00)80228-7

https://procure-oncology.com/wp-content/uploads/2023/10/Procure-icoRecurso-1@2x-100.jpg 0 0 miguel https://procure-oncology.com/wp-content/uploads/2023/10/Procure-icoRecurso-1@2x-100.jpg miguel2000-04-27 10:00:002000-04-27 10:00:00Liver xenotransplantation: changes in lipid and lipoprotein concentration after long-term graft survival

Filter by categories

  • Alemany’s & Piulats’s lab (133)
  • Antolin's lab (36)
  • Aytes's Lab (25)
  • Belver's Lab (25)
  • Casanovas's Lab (77)
  • Martínez-Balibrea's Lab (43)
  • Menendez's Lab (121)
  • Molleví's Lab (35)
  • Pujana's Lab (110)
  • Sin categoría (5)
  • Sureda's & Farre's Lab (312)
  • Viñals's lab (111)

Twitter

Tweets by ProcureICO
Program Against Cancer Therapeutic Resistance

CONTACT US

Campus IDIBELL
(L’Hospitalet del Llobregat)
Hospital Duran i Reynals, Gran Via 199,
L’Hospitalet del Llobregat,
Barcelona 08908
Tel. +34 93 260 7952

Campus IGTP-IJC
(Badalona)
Campus Can Ruti – IGTP – Building Muntanya,
Rd. Can Ruti, Camí de les escoles s/n,
Badalona, Barcelona 08916
Tel. +34 93 554 3069

Campus IDIBGI
(Girona)
Parc Hospitalari Martí i Julià de Salt, Dr. Castany s/n,
Salt, Girona 17190
Tel. +34 872 987 087

© Copyright - Edisenius
  • Privacy Policy
  • Cookie Policy
  • Legal Notice
GLUT1 glucose transporter gene transcription is repressed by Sp3. Evidence for...Signaling angiogenesis via p42/p44 MAP kinase cascade
Scroll to top
Manage cookie consent
To offer the best experiences, we use technologies such as cookies to store and/or access device information. Consent to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Failure to consent, or withdrawal of consent, may adversely affect certain features and functions.
Functional Always active
Storage or technical access is strictly necessary for the legitimate purpose of allowing the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. Storage or technical access that is used exclusively for anonymous statistical purposes. Without a requirement, voluntary compliance by your Internet service provider, or additional records from a third party, information stored or retrieved solely for this purpose cannot be used to identify you.
Marketing
Storage or technical access is necessary to create user profiles to send advertising, or to track the user on a website or several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
See preferences
{title} {title} {title}