• Twitter
  • Jobs
ProCURE oncology
  • HOME
  • ABOUT US
  • RESEARCH GROUP
    • Molleví’s Lab
    • Antolin’s Lab
    • Alemany’s & Piulats’s lab
    • Martínez-Balibrea’s Lab
    • Aytes’s Lab
    • Belver’s Lab
    • Pujana’s Lab
    • Menendez’s Lab
    • Sureda’s & Farre’s Lab
    • Casanovas’s Lab
    • Viñals’s lab
  • INNOVATION
  • NEWS
  • CONTACT
  • Menu Menu

NEWS

Pretransplantation EASIX predicts intensive care unit admission in allogeneic hematopoietic cell transplantation

View in PubMed
8 de September de 2021/in Sureda's & Farre's Lab/by miguel

Blood Adv. 2021 Sep 14;5(17):3418-3426. doi: 10.1182/bloodadvances.2021004812.

ABSTRACT

The Endothelial Activation and Stress Index (EASIX) is a laboratory-based prognosis index defined as creatinine × lactate dehydrogenase/platelets. When measured at pretransplantation evaluation (EASIX-PRE), it predicts allogeneic hematopoietic cell transplantation (alloHCT) mortality. This study explores its ability to predict intensive care unit (ICU) admission and validates EASIX-PRE predictive power for overall survival (OS) and nonrelapse mortality (NRM) in 167 consecutive patients undergoing alloHCT. EASIX-PRE was calculated retrospectively in all patients and transformed into log2 values (log2-EASIX-PRE). Log2-EASIX-PRE predicted ICU admission (hazard ratio [HR], 1.41; P < .001), OS (HR, 1.19; P = .011), and NRM (HR, 1.28; P = .004). The most discriminating EASIX-PRE cutoff value for risk of ICU admission was the 75th percentile (2.795); for OS and NRM, it was the median value (1.703). Patients with EASIX-PRE >2.795 had higher incidence of ICU admission in comparison with patients with lower EASIX-PRE values (day +180, 35.8% vs 12.8%; HR, 2.28; P = .010). Additionally, patients with EASIX-PRE >1.073 had lower OS (2 years, 57.7% vs 68.7%; HR, 1.98; P = .006) and higher NRM (2 years, 38.7% vs 18.5%; HR, 2.92; P = .001) than patients with lower EASIX-PRE results. Log2-EASIX-PRE was not associated with incidence of transplantation-associated microangiopathy, sinusoidal obstruction syndrome, or acute graft-versus-host disease. This study proposes EASIX-PRE as a prognostic tool to identify patients undergoing alloHCT at increased risk of severe organ dysfunction and who would therefore require ICU admission. Early identification of patients at high risk of severe events could contribute to personalized intervention design. Additionally, it validates the association between EASIX-PRE and OS and NRM in those undergoing alloHCT.

PMID:34495311 | PMC:PMC8525231 | DOI:10.1182/bloodadvances.2021004812

https://procure-oncology.com/wp-content/uploads/2023/10/Procure-icoRecurso-1@2x-100.jpg 0 0 miguel https://procure-oncology.com/wp-content/uploads/2023/10/Procure-icoRecurso-1@2x-100.jpg miguel2021-09-08 10:00:002021-09-08 10:00:00Pretransplantation EASIX predicts intensive care unit admission in allogeneic hematopoietic cell transplantation

Filter by categories

  • Alemany’s & Piulats’s lab (131)
  • Antolin's lab (36)
  • Aytes's Lab (24)
  • Belver's Lab (25)
  • Casanovas's Lab (77)
  • Martínez-Balibrea's Lab (43)
  • Menendez's Lab (121)
  • Molleví's Lab (35)
  • Pujana's Lab (110)
  • Sureda's & Farre's Lab (259)
  • Viñals's lab (111)

Twitter

Tweets by ProcureICO
Program Against Cancer Therapeutic Resistance

CONTACT US

Campus IDIBELL
(L’Hospitalet del Llobregat)
Hospital Duran i Reynals, Gran Via 199,
L’Hospitalet del Llobregat,
Barcelona 08908
Tel. +34 93 260 7952

Campus IGTP-IJC
(Badalona)
Campus Can Ruti – IGTP – Building Muntanya,
Rd. Can Ruti, Camí de les escoles s/n,
Badalona, Barcelona 08916
Tel. +34 93 554 3069

Campus IDIBGI
(Girona)
Parc Hospitalari Martí i Julià de Salt, Dr. Castany s/n,
Salt, Girona 17190
Tel. +34 872 987 087

© Copyright - Edisenius
  • Privacy Policy
  • Cookie Policy
  • Legal Notice
Insights into the mechanisms underlying aberrant SOX11 oncogene expression in...Specialist palliative and end-of-life care for patients with cancer and SARS-CoV-2...
Scroll to top
Manage cookie consent
To offer the best experiences, we use technologies such as cookies to store and/or access device information. Consent to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Failure to consent, or withdrawal of consent, may adversely affect certain features and functions.
Functional Always active
Storage or technical access is strictly necessary for the legitimate purpose of allowing the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. Storage or technical access that is used exclusively for anonymous statistical purposes. Without a requirement, voluntary compliance by your Internet service provider, or additional records from a third party, information stored or retrieved solely for this purpose cannot be used to identify you.
Marketing
Storage or technical access is necessary to create user profiles to send advertising, or to track the user on a website or several websites for similar marketing purposes.
Manage options Manage services Manage {vendor_count} vendors Read more about these purposes
See preferences
{title} {title} {title}